What was found
INSPECTION TYPE:C1, STA 1390 AT LONG 34R INTERCOSTAL AND INTERCOSTAL SPLICE CORRODED BEYOND LIMITS. REMOVED, FABRICATED AND REPLACED IAW DWG 56166674 SRM 51-1-20D, 51-1-21.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE:C1, STA 1390 AT LONG 34R INTERCOSTAL AND INTERCOSTAL SPLICE CORRODED BEYOND LIMITS. REMOVED, FABRICATED AND REPLACED IAW DWG 56166674 SRM 51-1-20D, 51-1-21.