What was found
INSPECTION TYPE:C123, AT RT WHEEL WELL, WING TO FVS FAIRING, VERTICAL SUPPORT FITTING CRACKED. FOR FABRICATION OF NEW VERTICAL SUPPORT FITTING SEE TIMCO PRINTED OP ERATION 50017. LOCATED AND DRILLED NEW FITTING IAW DC8 SRM 51-1-24. INSTALLED NEW FITTING IAW DC8 SRM 51-3-0. TORQUED O/B SKI FITTING BOLT IAW DC8 SRM 51-3-1. INSTALLED UPPER TRUNNION PANEL IAW DC8 SRM 51-3-0.