What was found
INSPECTION TYPE:C1 STA. 1160 AT STR. 20 - 19 RT, LONGERON TO FRAME ATTACH FITTINGS ARE CRACKED, (2 TOTAL). REMOVED, FABRICATED AND REPLACED FITTINGS I.A.W. DWG.4750418.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE:C1 STA. 1160 AT STR. 20 - 19 RT, LONGERON TO FRAME ATTACH FITTINGS ARE CRACKED, (2 TOTAL). REMOVED, FABRICATED AND REPLACED FITTINGS I.A.W. DWG.4750418.