What was found
INSPECTION TYPE: C1, FLOORBEAM ATTACH FITTING IS CRACKED AT STA. 160, LBL 60, STR. 21 LT. REMOVED, FABRICATED AND RTEPLACED FITTING I.A.W. DWG.3772916 AND SRM 51-1-20D.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE: C1, FLOORBEAM ATTACH FITTING IS CRACKED AT STA. 160, LBL 60, STR. 21 LT. REMOVED, FABRICATED AND RTEPLACED FITTING I.A.W. DWG.3772916 AND SRM 51-1-20D.