What was found
INSPECTION TYPE: C 123 SEAT TRACK AT STA 1575 HAS CORROSION AROUND SEAT TRACK PLUG, FOUND OUT OF LIMITS IAW DC8 SRM 53-2-3. CUT SEAT TRACK AT FS 1550 & AT PRODUCTION SPLICE AT 1590. FABBED FWD SPLICE PER DC8 SRM 53-2-3. LOCATED, DRILLED & INSTALLED NEW SECTION OF SEAT TRACK & SPLICES PER DC8 SRM 53-2-3, PARTS WERE ALODINED & PRIMED BEFORE INSTALLATION PER DC8 SRM 51-1-8.