What was found
INSPECTION TYPE: C123, AFT CARGO BAY FS 1020. CORROSION ON LOWER SURFACE OF UPPER FRAME FLANGE FROM LONGERON 36 - 35 LT. REMOVED CORROSION, FOUND TO BE BEYOND LIMITS IAW DC8 SRM 53-2-0. RMVD FRAME CAP FOR FOM, REMOVED DAMAGE IAW DWG DC8 53-0229. FABED REPAIR ANGLE & FILLERS IAW DWG DC8 53-0229. REMOVED CORROSION FROM FRAME CAP. FOUND TO BE BEYOND LIMITS IAW DC8 SRM 5 1-2-0, DRILLED NEW FRAME CAP PN 5764343-505 & INSTALLED IAW DC8 SRM 51-1-20, 51-1-24 & DWG DC8 53-0229.