What was found
INSPECTION TYPE:C2, T-ANGLE ATTACH BRACKET AND RIB AT STA 802 RRL 40 CORRODED. REMOVED 3641315-502 FITTING. REMOVED CORRODED DOUBLER. FAB NEW DOUBLER IAW DAC DWG 5773275. REMOVED CORROSION FROM WEB IAW DC8 SRM 51-1-8, WITHIN LIMITS IAW DC8 SRM 53-2-0. REMOVED CORROSION FROM 3641315-502, OUT OF LIMITS. LOCATED AND DRILLED NEW 3641315-502 FITTING IAW DC8 51-1-24. INSTALLED NEW DOUBLER, ATTACH ANGLE, AND FITTING IAW DC8 SRM 51-1-21 & 51-1-20D.