What was found
INSPECTION TYPE:N/A, RUDDER REMAINS ULTRA SENSITIVE AFTER T/O W/FLAPS UP AND YAW DAMPER ON OR OFF. MILD PRESSURE ON RUDDER PEDAL RESULTS IN LARGE YAW DEFLECTIONS IN FLIGHT. PERFORMED ADJ/TEST FOR RUDDER HYD PRESSURE REDUCER VALVE CHECK IAW MM 27-21-07. ACCOMPLISHED TASK NR 0224 FUNCTIONAL CHECK FOR RUDDER HIGH PRESSURE ANNUNCIATOR SYSTEM AND FOUND NORMAL. ALSO VERIFIED PHYSICALLY ALL COMPONENTS ON TAIL SECTION AND FOUND OK. OPERATED RUDDER SEVERAL TIMES, CHECKED NORMAL. UNABLE TO DUPLICATE PROBLEM. OK FOR SERVICE.