What was found
INSPECTION TYPE:C2, FWD LWR CARGO PIT AT FS 70 DOOR LWR FRAME IS CORRODED ON LWR FLANGE. REMOVED ANGLE, FAB NEW ANGLE IAW DAC DWG 5613064. ALODINED AND PRIMED IAW 51-1-8. INSTALLED ANGLE IAW DC8 SRM 51-1-20.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE:C2, FWD LWR CARGO PIT AT FS 70 DOOR LWR FRAME IS CORRODED ON LWR FLANGE. REMOVED ANGLE, FAB NEW ANGLE IAW DAC DWG 5613064. ALODINED AND PRIMED IAW 51-1-8. INSTALLED ANGLE IAW DC8 SRM 51-1-20.