What was found
INSPECTION TYPE:C2, INTERCOSTAL STA 1720 - 1740 L33R IS CRACKED. REMOVED INTERCOSTAL IAW DC8 SRM 51-1-21 & 51-1-20D. FABRICATED, INTERCOSTAL, LOCATED, AND DRILLED IAW DAC DWG NR 5649329 & DC8 SRM 51-1-24. ALODINED AND PRIMED IAW DC8 SRM 51-1-8. INSTALLED WITH HI-LOKS IAW DC8 SRM 51-1-20D.