What was found
INSPECTION TYPE:C123, IN THE AFT LOWER CARGO COMPT STA 1150 L35R, FITTING IS CRACKED. REMOVED FITTING IAW DC8 SRM 51-1-20D, LOCATED AND DRILLED NEW FITTING IAW DC8 SRM 51-1-24, FABRICATED DOUBLERS IAW DC8 SRM 53-2-0, ALODINED AND PRIMED IAW DC8 SRM 51-1-8, INSTALLED FITTING AND DOUBLERS IAW DC8 SRM 51-1-20D.