What was found
INSPECTION TYPE:C1, STA 1690 LONG 32L END HAS HOLES WITH NO EDGE DISTANCE. REMOVED AND REPLACED FITTING IAW DWG 4641324, AND SRM 51-1-20D.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE:C1, STA 1690 LONG 32L END HAS HOLES WITH NO EDGE DISTANCE. REMOVED AND REPLACED FITTING IAW DWG 4641324, AND SRM 51-1-20D.