What was found
INSPECTION TYPE:PFLT, NR 1 ENG A FIRE LIGHT WILL NOT TEST. ACCOMPLISH WAN 558661/REF DMI M 208397, NR 1 ENGINE B LOOP FIRE TEST INOP, TECH RECOMMENDS CHECK RESISTANCE BETWEEN PINS E AND G RESISTANCE CHECKED BETWEEN PINS E AND G, FOUND TO BE WITHIN LIMITS IAW MM 26-11-02. SYSTEM OPS CHECK, PERFORMED FOUND SATIS. THIS CLOSES DMI 208397.