What was found
INSPECTION TYPE:C, LEFT WW FRAME 930 HAS PREVIOUS REPAIR WITH STOP HOLE, BUT IS CONTINUING UPWARDS AFTER STOP HOLE FRAME BELOW FLOOR BS 930. PERFORMED HFEC INSP ON I/B FLANGE AS PER NDT MANUAL PART 6-51-00-01 FIG 4. CRACK AT 1/4 BOLTS HOLE APPROX .5 INCH DOWN FROM PRESSURE WEB, INSTALL DOUBLER REPAIR AS PER EO B727-5310-2611.