INSPECTION TYPE:N/A BOTH EMERGENCY LIGHTS INOP. REPLACED BATTERIES IN COCKPIT EMERGENCY LIGHTS. REPLACED EMERGENCY LIGHT ASSY OVER EXIT DOOR P/N ON AND OFF 10-0067, S/N OFF 42-11, S/N O N 27025. OPS CHECKS GOOD