What was found
INSPECTION TYPE:C6 M/D - BS 1241-1265 LBL 116 O/B LONGITUDINAL FLOOR SUPPORT FOUND CORRODED. FLOOR SUPPORT REPLACED AS PER SRM 51-10-01. CORROSION REMOVED IAW SRM 51-10-01. BLEND OUT COR. DEPTH 0.036 INCH, WIDTH 1INCH , LENGTH 2 INCH.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE:C6 M/D - BS 1241-1265 LBL 116 O/B LONGITUDINAL FLOOR SUPPORT FOUND CORRODED. FLOOR SUPPORT REPLACED AS PER SRM 51-10-01. CORROSION REMOVED IAW SRM 51-10-01. BLEND OUT COR. DEPTH 0.036 INCH, WIDTH 1INCH , LENGTH 2 INCH.