What was found
INSPECTION TYPE:C, LT BS 320 NOSE WHEEL WELL VERTICAL BEAM WEB FOUND CRACK AT NR 3 INSULATION BLANKET STAND - OFF HOLE (COUNT FROM TOP) APPROX .3125 INCH RUNNING UPWARD. VERTICAL BEAM WEB REPAIRED AND REPLACED AS PER SRM 51-10-01.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE:C, LT BS 320 NOSE WHEEL WELL VERTICAL BEAM WEB FOUND CRACK AT NR 3 INSULATION BLANKET STAND - OFF HOLE (COUNT FROM TOP) APPROX .3125 INCH RUNNING UPWARD. VERTICAL BEAM WEB REPAIRED AND REPLACED AS PER SRM 51-10-01.