What was found
INSPECTION TYPE:C LHW - UPPER SURFACE L/E FIXED PANEL BUTT JOINT AREA FOUND BULGE AT ILES 997 AFT OF NR 7 V.C. FLAP AS MARKED. L/E FIXED PANEL SUPPORT T-CHORD REPLACED AND RIB REINSTALLED AS PER SRM 51-30-02, 51-10-01 L/E PNEUMATIC DUCT TRUSS ROD AND TORQUE SHAFT REMOVED AND RECONNECTED AS PER MM 36-11-00, 20-51-01, 27-81-05.