What was found
INSPECTION TYPE:C2 U/D BS 320 BETWEEN STR 2L AND 3L WEB CRACKED. REPAIRED FRAME WEB PER SRM 51-40-02. (NDT CONFIRM NO CRACK BEYOND STOP HOLE AFTER STOP HOLE DRILLED PER SRM 51-10-01).
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE:C2 U/D BS 320 BETWEEN STR 2L AND 3L WEB CRACKED. REPAIRED FRAME WEB PER SRM 51-40-02. (NDT CONFIRM NO CRACK BEYOND STOP HOLE AFTER STOP HOLE DRILLED PER SRM 51-10-01).