As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
INSPECTION TYPE: C, LT BATH TUB FITTING 1EA BOLT HOLE CRACK AT AFT SURFACE AT 5 O'CLOCK POSITION ( LOOKING FWD ) APPROX 0.040 INCH IN LENGTH, LT BS 1000 BATH STUB FITTING REPLACED AND ATT BOLTS REINSTALLED. MM 20-51-01 AND SRM 51-10-01 PAGE 8.