What was found
INSPECTION TYPE: C, LT SIDE BS 800 BTN STR 16 - 17 FOUND TWO EACH FASTENER HOLES CRACKED AT STRAP RUNNING AFT FROM HOLE TO EDGE. REPAIRED FRAME STRAP AS PER RS R53-22-34680.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE: C, LT SIDE BS 800 BTN STR 16 - 17 FOUND TWO EACH FASTENER HOLES CRACKED AT STRAP RUNNING AFT FROM HOLE TO EDGE. REPAIRED FRAME STRAP AS PER RS R53-22-34680.