What was found
INSPECTION TYPE:C, LT SIDE BS 2231, TWO FASTENER HOLES CRACK REVEALED AT BETWEEN STR 24L AND STR 26L DRAWING ON REVEALED AREA. DETAIL PLEASE REFER ATT DRAWING. REVEALED REPAIRED PER HX RS R53-62-34682.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE:C, LT SIDE BS 2231, TWO FASTENER HOLES CRACK REVEALED AT BETWEEN STR 24L AND STR 26L DRAWING ON REVEALED AREA. DETAIL PLEASE REFER ATT DRAWING. REVEALED REPAIRED PER HX RS R53-62-34682.