What was found
INSPECTION TYPE:C1 FWD CARGO PIT STA 320 L 34R - 35R FITTING IS CORRODED. REMOVED Z-FITTING, FAB SPLICE AND DRILLED NEW FITTING IAW SRM 53-2-0, ALODINED AND PRIMED IAW SRM 51-1-8, INSTALLED IAW DC8 SRM 51-1-21D.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE:C1 FWD CARGO PIT STA 320 L 34R - 35R FITTING IS CORRODED. REMOVED Z-FITTING, FAB SPLICE AND DRILLED NEW FITTING IAW SRM 53-2-0, ALODINED AND PRIMED IAW SRM 51-1-8, INSTALLED IAW DC8 SRM 51-1-21D.