What was found
INSPECTION TYPE:C2, KEELBEAM AREA BETWEEN MLG DOORS STA 830, LT ATTACH ANGLE CRACKED. FABED AND INSTALLED NEW ATTACH ANGLE IAW DAC DWG 4645535 AND DC8 SRM 51-1-20D
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE:C2, KEELBEAM AREA BETWEEN MLG DOORS STA 830, LT ATTACH ANGLE CRACKED. FABED AND INSTALLED NEW ATTACH ANGLE IAW DAC DWG 4645535 AND DC8 SRM 51-1-20D