As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
INSPECTION TYPE: C2, AFT LWR CARGO PIT AT FS 1060 ABOVE LONG 33 RT - 36 FRAME IS CORRODED UND ER AND AROUND NUTPLATES. REMOVED CORROSION FOUND TO BE OUT OF LIMITS IAW 53-2-0 REMOVED FRAME CAP GUSSET & CLIP FOUND GUSSET DAMAGED, OUT OF LIMITS IAW 53-2-0 REC''''D LOCATED & DRILLED NEW FRAME CAP FAB REPAIR IAW STD 5310-602 FAB NEW GUSSET & CLIP IAW DAC DWG 9758507.