What was found
INSPECTION TYPE:X2 FWD CARGO PIT AT FS 500 - 520 INTERCOSTAL AT LONG 33R IS CRACKED. REMOVED OLD INTERCOSTAL, FABBED NEW PART TREATED AND PRIMED NEW PART, DRILLED, INSTALLED NEW PART ALL IAW DC8 SRM 51-1-8 AND DAC DWG 5616 520 & SRM 51-1-20D.