As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
INSPECTION TYPE:X2 AFT PIT FS 1152 FITTING AT L31R-L33R IS CRACKED. REMOVED BANANA FITTINGS AT STA 1152 & 1160 IAW DC8 SRM 51-1-20D, REC' D LOCATED AND DRILLED NEW FITTING AT STA 1152 IAW DC8 SRM 51-1-24 AND REINSTALLED NEW FITTING IAW DC8 SRM 51-1-20D.