What was found
INSPECTION TYPE:C1/3 LT WING FLAP HINGE SUPPORT FITTING XF 409.6673 INBOARD CRACKED AS MARKED. REMOVED FLAP LEADING EDGES I/B & O/B OF FLAP HINGE FITTING TO FOM. LOCATED & DRILLED NEW BASE FITTING. INSTALLED BUSHINGS, INSTALLED SPRING COVER, TRACK BASE FITTING COVER PLATES LEADING EDGE ATTACH ANGLES, FLAP FAIRING ATTACH ANGLE & LEADING EDGES IAW DC8 SRM 510D, 51.