What was found
INSPECTION TYPE:C2 AFT CARGO PIT AT FS 1170 AT LONG 33R T BOLT LATCH FITTING ATTACH FITTING IS CRACKED THROUGH FASTENER HOLES. REMOVED & REPLACED FWD & AFT SPLICE FITTING IAW DC8 SRM 51-1-20D.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE:C2 AFT CARGO PIT AT FS 1170 AT LONG 33R T BOLT LATCH FITTING ATTACH FITTING IS CRACKED THROUGH FASTENER HOLES. REMOVED & REPLACED FWD & AFT SPLICE FITTING IAW DC8 SRM 51-1-20D.