What was found
INSPECTION TYPE:C2 INTERCOSTAL IS CRACKED AT STA 1435 BL 0 ABOVE D-PIT DOOR. STOP DRILLED CRACK, NDT VERIFIED STOP DRILL TERMINATED CRACK, FABRICATED AND INSTALLED DOUBLER IAW SRM 53-2-0 FIG 1D.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE:C2 INTERCOSTAL IS CRACKED AT STA 1435 BL 0 ABOVE D-PIT DOOR. STOP DRILLED CRACK, NDT VERIFIED STOP DRILL TERMINATED CRACK, FABRICATED AND INSTALLED DOUBLER IAW SRM 53-2-0 FIG 1D.