What was found
INSPECTION TYPE:C MATERIAL LOSS INDICATION AT BS 259.5 AT STR.19 R/H. REMOVED FASTENERS IAW SRM 51-30-2. CORR NOT FOUND TO BE WITHIN LIMIT S IAW SRM 53-30-01. REPAIR CARRIED OUT AS REQUIRED IAW EO-B727-5310-1371 APPDX. E.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE:C MATERIAL LOSS INDICATION AT BS 259.5 AT STR.19 R/H. REMOVED FASTENERS IAW SRM 51-30-2. CORR NOT FOUND TO BE WITHIN LIMIT S IAW SRM 53-30-01. REPAIR CARRIED OUT AS REQUIRED IAW EO-B727-5310-1371 APPDX. E.