What was found
INSPECTION TYPE:C CRACKS FOUND IN NLG W/WELL PRESSURE WEB AT BS 269.5, 4" BELOW THE CE ILING ON THE R/H PRESSURE WEB AREA. NEW WEB AND DOUBLERS FABRICATED AND INSTALLED IAW DRAWING 65-18414
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE:C CRACKS FOUND IN NLG W/WELL PRESSURE WEB AT BS 269.5, 4" BELOW THE CE ILING ON THE R/H PRESSURE WEB AREA. NEW WEB AND DOUBLERS FABRICATED AND INSTALLED IAW DRAWING 65-18414