What was found
INSPECTION TYPE:C&SI SMALL BRACKET ATTACHING AFT END OF INTERCOSTAL TO FRAME AT BS 500 IS CRACKED, INTERCOSTAL IS LOCATED ABOVE STR. 26L IN LWR FWD CARGO BAY BRACKET REPLACED IAW SRM 51-20-1, FIG 7 & SRM 51-30-02
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE:C&SI SMALL BRACKET ATTACHING AFT END OF INTERCOSTAL TO FRAME AT BS 500 IS CRACKED, INTERCOSTAL IS LOCATED ABOVE STR. 26L IN LWR FWD CARGO BAY BRACKET REPLACED IAW SRM 51-20-1, FIG 7 & SRM 51-30-02