What was found
AREAS OF LIGHT SURFACE CORROSION ON UPPER CHORD OF FLOORBEAM BS 344 BETWEEN LBL 15 TO RBL 35. FLOORBEAM SECTION REPLACED IAW SRM 53-10-8 FIG 7 WITH REF TO BOEING DRG 65-16316.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AREAS OF LIGHT SURFACE CORROSION ON UPPER CHORD OF FLOORBEAM BS 344 BETWEEN LBL 15 TO RBL 35. FLOORBEAM SECTION REPLACED IAW SRM 53-10-8 FIG 7 WITH REF TO BOEING DRG 65-16316.