What was found
INSPECTION TYPE:C LWLG - BS 1241 BULKHEAD LBL 87 CENTER TANK TRANSFER VALVE BONDING JUMPER ATTACHMENT VERT STIFFENER CORRODED. CORROSION REMOVED IAW SRM 51-10-01. BLEND OUT NOT WITHIN SRM 57-10-01 LIMITS. LWLG BS 1241 LBL 87 VERTICAL STIFFENER REPLACED AS PER SRM 51-10-01 PG 8.