What was found
INSPECTION TYPE:C, NOSE W/W LT VERTICAL SIDEWALL WEB FOUND BULGE UP AT STA 380 WL 187. CORROSION REMOVED IAW SRM 51-10-01. BLEND OUT NOT WITHIN SRM 53-10-01 LIMITS, FOR REPAIR REFER TO RS R53-18-34814.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE:C, NOSE W/W LT VERTICAL SIDEWALL WEB FOUND BULGE UP AT STA 380 WL 187. CORROSION REMOVED IAW SRM 51-10-01. BLEND OUT NOT WITHIN SRM 53-10-01 LIMITS, FOR REPAIR REFER TO RS R53-18-34814.