What was found
INSPECTION TYPE:C R/H BS 2231 STR 24-26 AT REPAIR AREA FASTENER HOLES FOUND 1 EA FASTENER HOLE CRACK AT STRAP LAYER APPROX 3/16" INCH IN LENGTH AND CRACK END AS MARKED. FOR DETAIL PLS REFER ATTACHED SKETCH. REVEAL & STRAP REPAIRED AT BS 2231 RH FRAME BETWEEN STR 24-26 AREA AS PER RS R-52-61-34845.(UPS EO B747-5310-17209-A, APPENDIX A) REFER HAECO NRC#6215 FOR DETAIL.