What was found
INSPECTION TYPE:C R/H OF BS 1480 FUSELAGE SKIN AT EXTENSION FITTING SRES FOUND CRACK AT HOLE #11 RUNNING AT 5 O'CLOCK POSITION ( VIEW LOOKING I/B )WITH 1/16" IN LENGTH APPROX AT I/B SURFACE. RH BS 1480 FX SKIN AT HOLE #11 CRACK FREE FINAL SIZE 0.6875" & PLAN B REPAIR BUSHING INSTALL PER SB 53A2390 R.1 FIG 14. REFER HX RS R-53-43-34841 & UPS EO 5310-17208-A, A TIME LIMIT REPAIR FOR 12 MONTHS. POST MOD INSP PLAN PER SB 53A2390 & AD 2001-11-06.