As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
INSPECTION TYPE:C R/H OF BS 1480 B/H WEB SPLICE PLATE FOUND CRACK AT HOLE #15 LOCATED AFT SIDE SURFACE APPROX 1/16" IN LENGTH. RH BS 1480 BULKHEAD WEB SPLICE PLATE AT HOLE #15 FINAL SIZE 0.500" & PLAN B REPAIR BUSHING INSTALL PER SB 53A2390 R.1 FIG 14. REFER HX RS R-53-43-34841 & UPS EO 5310-17208-A, A TIME LIMIT REPAIR FOR 12 MONTHS. POST MOD INSP PLAN PER SB 53A2390 & AD 2001-11-06.