What was found
INSPECTION TYPE:C LH BS 1480 B/H #11 HOLE 2EA CRACK FOUND AT OUTER CHORD SPLICE FTG RUNNING FWD AT 8 O/C POSN & 7 O/C POSN (LOOKING I/B),CRACK AT 8 O/C POSN 3/16" LONG, CRACK AT 7 O/C POSN 0.040" LONG (CRACK AT O/B FACE) (STR L33 TO L34) LH BS 1480 B/H OUTER CHORD SPLICE FTG BOLT HOLE #11 REAMED TO 0.660" AS PER SB 747-53A2390 R1 AND BUSHING REINSTALLED CRACK FREE CONFIRMED AS PER NDT NTM PT 6 51-00-00 FIG 4.