What was found
INSPECTION TYPE:C U/D - BS 440-460 LBL 0 - RBL 50 FLOOR SUPPORT AND WEB FOUND CORR. BLEND OUT EXCEEDS SRM LIMIT, FLOOR SUPPORT REPLACED AS PER SRM 51-10-01 PG 8.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE:C U/D - BS 440-460 LBL 0 - RBL 50 FLOOR SUPPORT AND WEB FOUND CORR. BLEND OUT EXCEEDS SRM LIMIT, FLOOR SUPPORT REPLACED AS PER SRM 51-10-01 PG 8.