What was found
DURING C CHECK, CRACK FOUND AT RT SIDE OF BS 1350 OVERWING LONGERON, THE CRACK FOUND INITIATED FROM FWD EDGE OF VERTICAL FLANGE RUNNING TOWARD AFT TO I/B HORI FLANGE, TOTAL LENGTH OF CRACK 2 INCH LONG APPROXIMATELY. BS 1350 RT OVERWING LONGERON UPPER CHORD CRACKED AND CORRODED INTERIM REPAIR CARRIED OUT AS PER HX RS R-53-41-34906 & EA 747-53-20110 REPEAT INSPECTIONS EVERY 2000 FLTS PER REF 'F' SB747-53-2291 APPLY.