What was found
INSPECTION TYPE:C BS 540 UPPER DECK FLOORBEAM UPPER HORIZONTAL FLANGE, 1 EA FASTENER HOLE CRACK FOUND AT RBL 42, 1/8 INCHES LONG RUNNING AFT. FLOORBEAM AT BS 540 RBL 42 REPAIRED AS PER SRM 53-10-07 FIG 21.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE:C BS 540 UPPER DECK FLOORBEAM UPPER HORIZONTAL FLANGE, 1 EA FASTENER HOLE CRACK FOUND AT RBL 42, 1/8 INCHES LONG RUNNING AFT. FLOORBEAM AT BS 540 RBL 42 REPAIRED AS PER SRM 53-10-07 FIG 21.