What was found
INSPECTION TYPE:C2 STA 55 FRAME IS CRACKED AT ROD ATTACH POINT LONG 23R. CUT OUT DAMAGE, NDT VERIFIED NO CRACKS AT CUTOUT. FABRICATED AND INSTALLED FRAME AND SEGMENT IAW SRM 53-2-0 FIG 2.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE:C2 STA 55 FRAME IS CRACKED AT ROD ATTACH POINT LONG 23R. CUT OUT DAMAGE, NDT VERIFIED NO CRACKS AT CUTOUT. FABRICATED AND INSTALLED FRAME AND SEGMENT IAW SRM 53-2-0 FIG 2.