What was found
INSPECTION TYPE:C2 STA 200 LONG 20R WEB AND DOOR PAN ARE CRACKED AT R-1 DOOR AFT LOWER CORNER. CUT OUT DAMAGE, NDT VERIFIED NO CRACKS. FABRICATED AND INSTALLED REPAIR DOUBLERS ON PAN AND WEB IAW SRM 53-2-0 FIG 23 AND DWG 5615700.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE:C2 STA 200 LONG 20R WEB AND DOOR PAN ARE CRACKED AT R-1 DOOR AFT LOWER CORNER. CUT OUT DAMAGE, NDT VERIFIED NO CRACKS. FABRICATED AND INSTALLED REPAIR DOUBLERS ON PAN AND WEB IAW SRM 53-2-0 FIG 23 AND DWG 5615700.