What was found
INSPECTION TYPE:C2 CRACK INDICATIONS FOUND BY NDT ON HOLE NR 11 LT. REAMED AND COINED HOLE, FABBED AND INSTALLED BUSHING IAW REO G08603.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE:C2 CRACK INDICATIONS FOUND BY NDT ON HOLE NR 11 LT. REAMED AND COINED HOLE, FABBED AND INSTALLED BUSHING IAW REO G08603.