What was found
INSPECTION TYPE:C13 AFT PIT FS 1490 L33L SPLICE FITTING IS CORRODED. REMOVED SPLICE FITTING RECD LOCATED DRILLED IAW DC8 SRM 51-1-24, INSTALLED IAW DC8 SRM 51-1-20D.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE:C13 AFT PIT FS 1490 L33L SPLICE FITTING IS CORRODED. REMOVED SPLICE FITTING RECD LOCATED DRILLED IAW DC8 SRM 51-1-24, INSTALLED IAW DC8 SRM 51-1-20D.