What was found
INSPECTION TYPE:C13 AFT CARGO PIT AT FS 1180 BETWEEN LONG 33R - 34R Z-FITTING IS CRACKED. REMOVED CORROSION PER DC8 SRM 51-1-8, FOUND TO EXCEED LIMITS PER DC8 SRM 53-2-0. REMOVED PLD FITTING PER DC8 SRM 51-1-20D, LOCATED AND DRILLED NEW FITTING AND REPAIR ANGLES PER DC8 SRM 53-2-0 FIG G, INSTALLED FITTING AND ANGLES PER DC8 SRM 51-1-20D.