What was found
INSPECTION TYPE:C2 CORROSION BETWEEN LONGERON AND FRAME ATTACH PLATE AFT OF TORQUE BOX STA 1160 AT LONG 35R TO 33R WEB IS CORRODED BEYOND LIMITS. REMOVED EXISTING DOUBLER, CUT OUT CORRODED SECTION OF WEB, FABRICATED AND INSTALLED WEB SECTION, SPLICE PLATES, FRAME REPAIR ANGLES, CLIPS, INTERCOSTAL, AND UPPER TORQUE BOX WEB IAW DWG 9754949, 3753772, 9754947, 5753893, AND SRM 53-2-0 FIG 1B, DC8-5310-11728-A APPX A.