What was found
INSPECTION TYPE:C2 EMERGENCY EXIT LIGHTS FAILED OPS CHECK. RANG OUT WIRING PER WDM 33-50-01, WIRING CHECKED OUT GOOD. REMOVED AND REPLACED EMERGENCY LIGHTS BATTERY PACK, AND OPS CHECKED GOOD IAW DC8 M/M 33-50-01.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE:C2 EMERGENCY EXIT LIGHTS FAILED OPS CHECK. RANG OUT WIRING PER WDM 33-50-01, WIRING CHECKED OUT GOOD. REMOVED AND REPLACED EMERGENCY LIGHTS BATTERY PACK, AND OPS CHECKED GOOD IAW DC8 M/M 33-50-01.